A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2125C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   BK PRECISION 2125C   Description / Specification:   Spec Sheet 
BK PRECISION 2125C 2 Ch 30 MHz Analog Oscilloscope

The B+K Precision 2125C is a dual trace 30 MHz oscilloscope that offers high performance and a built in component tester for capacitors, inductors, diodes, transistors, zener diodes. Specifications. Frequency Response 5 mV to 5 V/div: DC to 30 MHz (-3dB). Frequency Response X5: DC to 10 MHz (-3dB). Sensitivity: 5 mV/div to 5 V/div, 1 mV/div to 1 V/div at x5. Attenuator: 10 steps in 1-2-5 sequence, Vernier control provides full adjustment between steps. Accuracy: ±3%, ±5% at x5. Input impedance: 1 M-ohm ±2%. Input Capacitance: 25 pF ±10pF. Rise Time: 12 ns (Overshoot <=5%). Maximum Input Voltage: 400V (DC + AC peak). Sweep Time: 0.1 µs/div to 2 s/div. Sweep Operating Modes: Main, mix (both main sweep and delay sweep displayed), or Delay (only delay sweep displayed), X-Y. Triggering Modes: AUTO (free run) or NORM, TV-V, TV-H. X-Y Mode: Switch selectable using X-Y switch. CH 1: X axis, CH 2: Y axis. Accuracy: Y-Axis; ±3%, X-Axis; ±6%. Frequency Response: DC to 1 MHz typical (-3 dB), to 6 div horizontal deflection. CRT Type: 6-inch rectangular with internal graticule. Components Tested: Resistors, capacitors, inductors, and semiconductors. Test Voltage: 6 V rms maximum (open). Test Current: 11 mA maximum (shorted).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2125C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your BK PRECISION 2125C CALIBRATION and/or BK PRECISION 2125C 2 Ch 30 MHz Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: